Radiation Alert Area Monitor 1×1

Radiation Area Monitor

Part # NMRAM1x1 Category Tag

Have questions about buying this product?

Chat with a Nomo Specialist

The Radiation Alert® Area Monitor is one of the most user friendly, all inclusive, state of the art radiation area monitors available. The easy to use interface is an intelligent resistive touch screen display featuring a large five digit LED readout.

The AM1X1 comes with either an internal or external Sodium Iodide Scintillation Detector. Cesium Iodide probes available. Rugged, wall mount enclosure options are available for high traffic areas. Monitor every Radiation Alert® Area Monitor on your network with the free software. Includes user selectable warning indicators for low and high radiation alarm levels, and detector failure. Setup email and text alerts to receive alarms while on the go. All the settings are stored internally, even when power is disconnected. All units come with a Certificate of Conformance. NIST Source calibrations available upon request.

Internal or External Probe Options Available.

Applications & Uses: Room monitoring for Hospitals, X-Ray machines, Accelerators, Laboratories, etc. Portal monitoring, such as doors and walkways, Source monitoring, Alarms in the presence of radiation or the absence of sources

Model

AM 1×1, AM 2×2, AM 7128, AM 71313, AM 7149

This product has no features.

Detector AM 1×1

1X1 NaI(Tl) Scintillation Probe.

Custom Probe Options Available. Tell us about your application and we can recommend the best probe options for your needs.

Sensitivity

Approximately 2500 CPM/mR/hr (137 Cs)

Operating Range

0.1  to 10 mR/hr (0.1 to 100 µSv/hr)

Energy Range

30 KeV – 2 MeV

Linearity

NIST Calibrated readings within 10% of true value with detector connected

Touch Screen Display

4.3 inch TFT 480×272 touch screen display with user friendly Programmable Units of Measurement and Audio and Visual Alarms. 5-digit LED display with 3 cm (1.5 in.) character height. 65K true colors capable of displaying full color images, animations, icons.

Base Units

Can display in µR/hr, mR/hr, µSv/hr, mSv/hr, CPM, KCPM, CPS, KCPS,

Instrument Settings

Settings for Base Units, Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software

Response

Varies automatically from 20 seconds to 2 seconds

Indicators

Ultra-Bright Strobe and Audible Alarm can trigger up to three relays with DB-9 serial connection, USB VCP for computer data logging, can also be used to control the unit with use of remote software for alarm indication and acknowledgment (Silence by remote),

High Voltage

User adjustable from 200 to 1200 volts

Power

12 VDC wall mount adapter included.

Battery Life

Typically 6 hours in non-alarm condition; 5 hours in alarm condition

Battery Charger

SLA Battery is continuously trickle charged when the instrument is connected to line power and turned on

Temperature Range

-10° to +50°C (14° to 122°F)

Humidity

10% to 70% Non-Condensing.

Size

20.3 x 28.6 x 10.8 cm (8 x 11.25 x 4.25 in.)

Construction

Easy mount steel enclosure

Includes

Management software for use with networked area monitors, Base Unit, Power Supply, Mounting Clips, C to C Cable (External Versions Only).

Options

External Strobe and Horn, External Detector, NIST Calibration
10 Base-T connection for use with remote software for alarm indication and acknowledgment (Silence by remote) Construction

Rugged case for wall mounting external detectors for area, room, and portal monitoring.

Limited Warranty

1 year limited warranty

External strobe and horn

Optional Second Remote Alarm

When you need secondary or backup alerts in other areas, connect the optional remote alarm for additional coverage.

Detector 2X2 Nal(Tl) Scintillation Probe

Custom Probe Options Available. Tell us about your application and we can recommend the best probe options for your needs.

Energy Range

30 KeV – 2 MeV

Sensitivity

Approximately 9000 CPS/mR/hr (137 Cs)

Operating Range

0.1 to 2 mR/hr (0.1 to 20 µSv/hr)

Response

Varies automatically from 20 seconds to 2 seconds

Touch Screen Display

4.3 inch TFT 480×272 touch screen display with user friendly Programmable Units of Measurement and Audio and Visual Alarms. 5-digit LED display with 3 cm (1.5 in.) character height. 65K true colors capable of displaying full color images, animations, icons.

Base Units

Can display in µR/hr, mR/hr, µSv/hr, mSv/hr, CPM, KCPM, CPS, KCPS,

Base unit Settings

Settings for Base Units, Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software

Indicators

Ultra-Bright Strobe and Audible Alarm can trigger up to three relays with DB-9 serial connection. USB VCP for computer data logging, can also be used to control the unit with use of remote software for alarm indication and acknowledgment (Silence by remote).

Ethernet

10 Base-T connection for use with remote software for alarm indication and acknowledgment (Silence by remote)

High Voltage

User adjustable from 200 to 1200 volts

Power

12 VDC wall mount adapter included

Battery Life

Typically 6 hours in non-alarm condition; 5 hours in alarm condition

Battery Charger

SLA Battery is continuously trickle charged when the instrument is connected to line power and turned on

Temperature Range

-10° to +50°C (14° to 122°F)

Humidity

10% to 70% Non-Condensing.

Size

20.3 x 28.6 x 10.8 cm (8 x 11.25 x 4.25 in.)

Construction

Easy mount steel enclosure

Includes

Management software for use with networked area monitors, Base Unit, Power Supply, Mounting Clips, C to C Cable.

Options

External Strobe and Horn, NIST Calibration, Rugged external mounting enclosure.

Rugged case for wall mounting external detectors for area, room, and portal monitoring.

Size

28.54 x 33.62 15.24 cm (11.24 x 13.24 x 6 in)

Limited Warranty

1 year limited warranty

Detector LND 7128 Energy Compensated GM Detector

Custom Probe Options Available. Tell us about your application and we can recommend the best probe options for your needs.

Energy Sensitivity

18 cps/mR/hr

Response Time

Varies automatically from 20 seconds to 2 seconds

Operating Range

0.1 to 200 mR/hr (0.1 to 2000 µSv/hr)

Linearity

NIST Calibrated readings within 10% of true value with detector connected

Touch Screen Display

4.3 inch TFT 480×272 touch screen display with user friendly Programmable Units of Measurement and Audio and Visual Alarms. 5-digit LED display with 3 cm (1.25 in.) character height. 65K true colors capable of displaying full color images, animations, icons.

Base Units

Can be set in µR/hr, mR/hr, µSv/hr, mSv/hr, CPM, kCPM, CPS, kCPS

Base unit Settings

Settings for Base Units, Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software

Indicators

Ultra-Bright Strobe and Audible Alarm can trigger up to three relays with DB-9 serial connection. USB VCP for computer data logging, can also be used to control the unit with use of remote software for alarm indication and acknowledgment (Silence by remote)

Ethernet

10 Base-T connection for use with remote software for alarm indication and acknowledgment (Silence by remote)

High Voltage

User adjustable from 200 to 1200 volts

AM-External GM

Area monitor base control unit with external GM detector.

.

Optional Second Remote Alarm

When you need secondary or backup alerts in other areas, connect the optional remote alarm for additional coverage.

Detector LND 71313 Energy Compensated GM Detector

Custom Probe Options Available. Tell us about your application and we can recommend the best probe options for your needs.

Sensitivity

7.5 cps/mR/hr

Dead Time

User adjustable to compensate for dead time of the detector and electronics

Operating Range

0.1 to 1500 mR/hr (0.1 – 15,000 µSv/hr)

Response Time

Varies automatically from 20 seconds to 2 seconds

Touch Screen Display

4.3 inch TFT 480×272 touch screen display with user friendly Programmable Units of Measurement and Audio and Visual Alarms. 5-digit LED display with 3 cm (1.5 in.) character height. 65K true colors capable of displaying full color images, animations, icons.

Base Unit Settings

Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software.

Base Units

Can be set in µR/hr, mR/hr, µSv/hr, mSv/hr, CPM, kCPM, CPS, kCPS

Base unit Settings

Settings for Base Units, Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software

Linearity

NIST Calibrated readings within 10% of true value with detector connected

Indicators

Ultra-Bright Strobe and Audible Alarm. Can trigger up to three relays with DB-9 serial connection. USB VCP for computer data logging, can also be used to control the unit with use of remote software for alarm indication and acknowledgment (Silence by remote).

Ethernet

10 Base-T connection for use with remote software for alarm indication and acknowledgment (Silence by remote)

High Voltage

User adjustable from 200 to 1200 volts

Power

12 VDC wall mount adapter included.

Battery Charger

SLA Battery is continuously trickle charged when the instrument is connected to line power and turned on

Battery Life

Typically 5 hours in non-alarm condition; 6 hours in alarm condition

Temperature Range

-10° to +50°C (14° to 122°F)

Humidity

10% to 70% Non-Condensing.

Construction

Easy mount steel enclosure

Size

20.3 x 28.6 x 10.8 cm (8 x 11.25 x 4.25 in.)

Includes

Management software for use with networked area monitors, Base Unit, Power Supply,

Options

External Strobe and Horn, External Detector and 50’ C to C coax cable, NIST Calibration Limited

Warranty

1 year limited warranty

Detector LND 7149 Energy Compensated GM Detector

Custom Probe Options Available. Tell us about your application and we can recommend the best probe options for your needs.

Energy Sensitivity

1.5 cps/mR/hr

Operating Range

0.1 to 16,000 mR/hr (0.1 to 160,000 µSv/hr)

Linearity

NIST Calibrated readings within 10% of true value with detector connected

Touch Screen Display

4.3 inch TFT 480×272 touch screen display with user friendly Programmable Units of Measurement and Audio and Visual Alarms. 5-digit LED display with 3 cm (1.5 in.) character height. 65K true colors capable of displaying full color images, animations, icons.

Base Unit Settings

Alarms and Calibration Information can be accessed through the Touch Screen Display or through the software.

Base Units

Can be set in µR/hr, mR/hr, µSv/hr, mSv/hr, CPM, kCPM, CPS, kCPS

Indicators

Ultra-Bright Strobe and Audible Alarm
Can trigger up to three relays with DB-9 serial connection
USB VCP for computer data logging, can also be used to control the unit with use of remote software for alarm indication and acknowledgment (Silence by remote)

Ethernet

10 Base-T connection for use with remote software for alarm indication and acknowledgment (Silence by remote)

High Voltage

User adjustable from 200 to 1200 volts

AM-External GM

Area monitor base control unit with external GM detector.

Optional Second Remote Alarm

When you need secondary or backup alerts in other areas, connect the optional remote alarm for additional coverage.

Power

12 VDC wall mount adapter included

Battery Life

Typically 6 hours in non-alarm condition; 5 hours in alarm condition

Battery Charger

SLA Battery is continuously trickle charged when the instrument is connected to line power and turned on

Temperature Range

-10° to +50°C (14° to 122°F)

Humidity

10% to 70% Non-Condensing.

Size

20.3 x 28.6 x 10.8 cm (8 x 11.25 x 4.25 in.)

Construction

Easy mount steel enclosure

Includes

Management software for use with networked area monitors, Base Unit, Power Supply.

Options

External Strobe and Horn, Remote detector with 50’ coax, NIST Calibration

Limited Warranty

1 year limited warranty

This product has no accessories.
This product does not have software options.
Login to NOMO

NOMO Deals

Get the best offers in NDT products.