DMQ QH7 U HEAVY-DUTY UCI Hardness testers[:es]DMQ QH7 L Rebound Hardness Tester “Leeb”

Ultrasonic Contact Impedance[:es]Hall Effect Thickness Gauge

Have questions about buying this product?

Chat with a Nomo Specialist

Our QH7 U is a HEAVY-DUTY UCI hardness tester that is factory pre-calibrated for steel while for other metals you can calibrate in very simple steps using reference blocks of the same material.

All QH7 models include rechargeable batteries and a Data Logger to store 32000+ measurements that can be transferred to a PC via Bluetooth o USB using DMQ DataCenter software.

[:es]

Our QH7 HEAVY-DUTY Leeb hardness testers use DMQ impact devices with CalTag technology so that you don’t have to calibrate the unit when changing devices and GyroTag technology so that the impact angle is automatically recognized.

All QH7 models include rechargeable batteries and a Data Logger to store 32000+ measurements that can be transferred to a PC via Bluetooth o USB using DMQ DataCenter software.

Model

QH7 C, QH7 L, QH7 U

Measure

  • Ultrasonic Contact Impedance (UCI)
  • Native unit is Vickers
  • Resolution ± 1HV
  • Accuracy ± 5% HV

UCI Probe

  • Loads:
    10N
    50N 

    With CalTag technology DMQ probes can be changed or replaced without having to calibrate the electronic unit

Measuring Angles

  • Measure in all directions

Features

  • Automatic hardness unit conversions
  • User defined units
  • Direct access key
  • Realtime graphics
  • Realtime statistics
  • Alarms
  • Selectable view modes
  • Measuring modes
  • Internal clock

Graphic LCD Display

  • LCD 128×64 pixels
  • RGB color LED backlight illumination (ON, OFF, Auto)
  • Adjustable digital contrast

Alarms

  • Low & High, user defined
  • Number of impacts
  • Alarm Types
    Visible: Flashing backlight and irregular digits
    Audible: Intermitent beep

Multi-Language

  • English
  • Spanish
  • Portuguese

Materials

  • Steel (Precalibrated from factory)
    Other materials require calibration on reference blocks

Units

  • HV (vickers)
  • HB (Brinell)
  • HRC (Rockwell C)
  • HRB (Rockwell B)
  • HS (Shore)
  • Rm (Mechanical Ressistance)
  • User Units
    Up to 8

Connection

  • USB
  • Bluetooth
  • RS232 (optional cable)

Data Logger

  • 32000 readings that can be sent to a PC using DMQ DataCenter software
  • 8 folders with 10 character alphanumeric naming
  • 2 capture modes
    Manual: Touch “Store” key
    Auto: Automatically stores values
  • Date and time register

Connectors

  • USB (cable included)
  • Type Lemo 0B 3-pin impact device connector
  • Type Lemo 00 UCI probe connector

Warranty

  • 5 year limited on electronics
  • 6 months on accessories

Measuring Ranges

  • Steel
    100-940 HV (Vickers)
    95-500 HB (Brinell)
    20-68 HRC (Rockwell C)
    55-100 HRB (Rockwell B)
    32-97 HS (Shore)
    275-2194 N/mm2 (Rm)
  • Aluminum
    44-189 HV (Vickers)
    40-160 HB (Brinell)
    28-91 HRB (Rockwell B)
  • Copper
    40-130 HV (Vickers)
    75-120 HB (Brinell)
    2-67 HRB (Rockwell B)
  • Brass
    45-196 HV (Vickers)
    42-169 HB (Brinell)
    10-93 HRB (Rockwell B)

    Conversions according to ASTM E140 standards

 

Model Upgrade Licenses

  • Upgrade to a QH7 C with the purchase of a license and a DMQ impact device

Power Supply

  • 2 x AA 1.2v Ni-MH Rechargeable
  • USB cable, cell phone charger

Dimensions

  • W: 165mm / 6.5in
  • H: 65mm / 2.55in
  • L: 105mm / 4.13in

 

DMQ QH7 U standard configuration

DMQ QH7 U electronic unit
DMQ UCI 10N or 50N probe
Coupling paste
USB cable
Pendrive with DMQ DataCenter software
High impact carrying case
Certificate of conformity

Measure

Method:
Ultrasonic Contact Impedance
Resolution:
1 HB, 1HV, 0.1HRC, 0.1 HRB
0.1 HRB, 0.1 HS, 1 N/mm2
Accuracy:
+/- 5% HV
Materials:
Steel (Precalibrated from factory)
Other materials require calibration on reference blocks
Measuring Range:
100HV to 940HV

UCI Probe

Types:
10N, 50N
Indentor:
Diamond pyramid
Indentation Depths:
10N

300HV – 12um
500HV – 9um
800HV – 7um
50N
300HV – 28um
500HV – 20um
800HV – 16um
Surface Roughness:
5N
– 1.52μm
10N
– 2.5μm
Minimum thickness:
5mm / 0.2″
Minimum weight:
0.4kg / 0.88lbs
Connector:
Type Micro-Dot
Probe Body:
Stainless steel

With CalTag technology DMQ probes can be changed or replaced without having to calibrate the electronic unit.

Features

Histogram:
3 to 10 bar graphic representations
Real Time Statistics:
Max, Min, Mean, Range and Standard Deviation
User Units:
2 user units can be established
Direct Access Key:
Set to change hardness unit, to save to memory or to open files
View Modes:
4 numerical modes: different information is displayed
Graphic mode: view histogram graphics
Measure Modes:
Absolute: displays the actual measured value
Differential: displays the difference between the real value and a nominal reference value
Internal Clock:
Time and date

Data Logger

Storage:
Up to 32000+ readings
Data Transfer:
Send to a PC using DMQ DataCenter software included at no additional charge
Organization:
8 files with 10 character alphanumeric naming
Capture Modes:
Manual: Touch the “Store” key to store values
Continuous: Automatically stores values
Date and Time Register:
Register day and time

Alarms

Low & High:
User defined
Alarm Types:
Visible: flashing backlight or irregular digits
Audible: intermitent beep

Display

Graphic LCD:
128×64 pixels
Viewable Area:
74 x 40mm / 2.9 x 1.57in
Backlight:
RGB color LED backlight (ON, AUTO, OFF)
Contrast:
Digital 30 steps

User Interface

Languages:
English, Spanish, Portuguese
Menu Screens:
Icon based
User ID:
Personal information with password protection

Units

Native HV (Vickers)

Conversions according to ASTM-140 and DIM 50150 standard
HB (Brinell)
HRC (Rockwell C)
HRB (Rockwell B)
HS (Shore)
Rm (Mechanical Ressistance)

Material Units

Up to 8

Hardness Ranges

Steel :
100-940 HV (Vickers)
95-500 HB (Brinell)
20-68 HRC (Rockwell C)
55-100 HRB (Rockwell B)
32-97 HS (Shore)
275-2194 N/mm2 (Rm)

For metals other than steel you must use reference blocks for calibration.

Aluminum:
44-189 HV (Vickers)
40-160 HB (Brinell)
28-91 HRB (Rockwell B)
Copper:
40-130 HV (Vickers)
75-120 HB (Brinell)
2-67 HRB (Rockwell B)
Brass:

45-196 HV (Vickers)
42-169 HB (Brinell)
10-93 HRB (Rockwell B)

Model Upgrade Licenses

Upgrade to a QH7 C with the purchase of a license and a DMQ impact device.

Connections

Connect to PC:
Bluetooth
USB (cable included)
RS232 (optional cable)
Printers:
Thermal printer with a USB cable
40 column printers with an RS232 cable

Front Panel

Keypad:
Membrane keypad

Electronic Unit

Dimensions:
W: 165mm / 6.5in
H: 65mm / 2.55in
L: 105mm / 4.13in
Weight:
200g / 7.05oz with batteries
Working Temperature:
-10°C to 50°C / 14°F to 122°F
Storage Temperature:
-20°C to 60°C / -4°F to 140°F
Enclosure:
Aluminium with rubber sides for easy grip

Power Supply

Batteries:
2 x AA 1.2v Ni-MH Rechargeable
Charge:
USB cable or cell phone charger
Battery Life:
40 hours with backlight off
Battery Indicator:
On all screens with a low level alarm
Auto-Off:
Programmable 1 to 120 minutes

Warranty

Electronic Unit:
5 year limited warranty
Impact Devices::
6 months

This product has no accessories.
This product does not have software options.
Login to NOMO

NOMO Deals

Get the best offers in NDT products.